Skip to content

Phase 7 — Climate UI

Live “now” screen on the ST7789: SHT40 temperature/humidity + BMP390 pressure. No new wires. Optional tact switch / LED / buzzer later.

Phase 7 - Climate UI mock

On screen Source
Climate title chrome
Large orange °C SHT40 temperature
Large cyan % SHT40 relative humidity
Large green hPa BMP390 pressure
Serial lines same three values @ ~1 Hz

Firmware

Changed. New folder firmware/07-climate-ui/ · src/main.cpp

Estardyn 2.0″ bring-up (same as Phase 6):

SPI.begin(SCK=12, MISO=-1, MOSI=11, SS=CS)
tft.init(240, 320);   // not 240x240
tft.setRotation(0);   // SPI_MODE0 default

Preconditions

  • Checkpoint 6 passed (RGB fill visible)
  • Phases 2–6 wiring still on (TFT power + SPI, sensor power + I2C)

7.1 Flash

Stop any serial monitor on COM first.

cd firmware/07-climate-ui
pio run -e esp32-s3-n16r8 -t upload --upload-port /dev/ttyACM0
Connected to ESP32-S3 on /dev/ttyACM0:
…
Hash of data verified.
Hard resetting via RTS pin...
========================= [SUCCESS] Took 11.45 seconds =========================
pio device monitor -b 115200 --port /dev/ttyACM0
weather climate-ui — phase 7
SDA=8 SCL=18  SPI SCK=12 MOSI=11 CS=10 DC=9 RST=7
UI live — ~1 Hz
temp_c=25.42  humidity=86.1  pressure_hpa=1010.30
temp_c=25.44  humidity=85.7  pressure_hpa=1010.30
temp_c=25.44  humidity=85.4  pressure_hpa=1010.32

This bench: serial streams ~25 °C / mid-80s % RH / ~1010 hPa @ ~1 Hz. TFT should show the Climate layout above with matching numbers (rounded).


7.2 Validate

  1. TFT shows title + three labelled values (not a black/blank panel).
  2. Numbers move when you breathe on the SHT40.
  3. Serial temp_c / humidity / pressure_hpa match the screen within rounding.
  4. No SPI/I2C fights (screen stays live; serial keeps printing).

7.3 If blank (serial OK)

Serial printing but a dark panel means SPI/backlight wiring or a bad init — not the climate sensors.

  1. Confirm BL and VDD still on 3V3 (Phase 2).
  2. Reseat all five SPI wires from Phase 6: GPIO12→SCL, 11→SDA, 10→CS, 9→DC, 7→RES/RST.
  3. TFT SDA must not share the I2C SDA net (GPIO8).
  4. Module is 4-SPI (silk R3+R5).
  5. Do not flash init(240, 240, SPI_MODE3) — that blanks this Estardyn 240×320.
  6. Fall back: flash firmware/06-tft-fill. If RGB still fails, fix wiring before retrying Phase 7.

Checkpoint 7

  • [x] Readable live climate screen on the TFT (see Phase 9 bench photo)
  • [x] UI matches serial within rounding
  • [x] Logged in lab-log.md

Stop here until checkpoint passes.